故障现象
笔者某次配置了一个16日的AM模块。出现了一个奇怪的问题。配置好后,拨入时没有Modem拨号声。只有电话的声。并且音指示灯也不亮。当笔者拔下模块上的电话线时。指示灯亮了。
[b]配置[/b]
620#sh run
Building configuration...
Current configuration : 866 bytes
!
version 12.2
service timestamps debug uptime
service timestamps Jog uptime
no service password-encryption
!
hostname2620
enable secret 5 $1$pUrf$9xGOg.zyxKawi9NljLHHr1
usernameuser password 0 Cisco
ip subnet-zero
!
!
no ip domain-lookup
!
!
!
!
interface FastEthernet0/0
ip address 136.0.0.254255.255.0.0
duplex auto
speed auto
!
interface Group-Async1
ip unnumbered FastEthernet0/0
encapsulation ppp
async default routing
async mode interactive
peer default ip address pool lab
ppp authentication chap
group-range 33 48
!
!
ip classless
no ip http server
ip pim bidir-enable
!
!
line con 0
password cisco
line 33 48
login local
modem InOut
autocommand ppp
transport input all
autoselect ppp
stopbits 1
flowcontrol hardware
line aux0
line vty 0 4
password Cisco
login
!
no scheduler allocate
end
诊断过程
笔者仔细检查配置文件,发现缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),没有效果。后来笔者想到拨号采用的都是模拟信号,与接地有很大关系。没自动应答:多半是接地问题。所以直接把路由器上的接地螺钉,用一根导线接到防静电地板下面的铁支柱上,问题解决了。
排除心得
路由器标准接地的方法是在铺设电源线的时候放置一根地线,然后路由器的外壳接到地线上去就好?,笔者估计原来负责网络系统搭建的厂商采用的电源线忽略了地线,否则也不会出现这样的问舰。接路由器电源的时候如果有地线,一般不需要我们再接地了。正文:http://www.qqread.com/route/m551299008.html
相关图文阅读
频道图文推荐
健 康 咨 询
时 尚 咨 询
相关专题
- 路由器设置专题 (2378篇文章)
- 交换机与路由器密码恢复 (3933篇文章)
- 路由故障处理手册 (2441篇文章)
- 路由安全配置专题 (11761篇文章)
- Cisco路由器配置手册 (4742篇文章)
- 无线宽带路由器 (7351篇文章)
- 网络故障手册 (14465篇文章)
- 操作系统常见故障解析 (4392篇文章)
- Linux下的路由的配置与应用 (11721篇文章)
- 路由故障处理 (93篇文章)
- 双路由器引起的地址竞争故障 (436次浏览)
- 全向VPN宽带路由器网络方案 (331次浏览)
- 无法上网 路由器设置变动惹的祸? (140次浏览)
- 3640路由器拨号设置 (132次浏览)
- 网络打印用途宽带路由器选购指南 (120次浏览)
- 给路由器重新分配路由 (114次浏览)
- 如何用好双WAN路由器 (109次浏览)
- 拒绝遗忘 路由器密码轻松恢复 (105次浏览)
- CISCO学习问题之OSPF如何做路由总结? (101次浏览)
- Cisco路由器安装向导 (91次浏览)